top of page
Screenshot 2024-09-02 at 12.33.02.png

E&E Lab Clinical Tests

E&E Lab has developed measurements and indicators to verify the functions of microcurrent products, such as keratin hydration, water loss, pore size, and skin sensitivity.

Comparing the Difference Between Current and No Current

Experimental Method:

1. Before applying the mask, assess both sides of each subject's cheeks.

2. Cut the mask in half and apply the printed microcurrent side to one half of the face and the non-printed (blank) mask material to the other half, as shown in the figure provided.

 

Detection Times:

- T0: Before using the mask

- T15min, T2hr, T4hr, T8hr: Time intervals after using the mask

 

Skin Detection Instruments:

- MoistureMeter SC: Measures skin hydration.

- VapoMeter: Detects TEWL (Trans-Epidermal Water Loss) from the skin.

- Antera 3D: Analyzes facial images, including wrinkles, texture, pigmentation, redness, and more.

Picture2(8).png

Hydration Detection: Assess the difference in the Improvement Rate (IR) between using microcurrent and no-current masks using the MoistureMeter SC. Higher values indicate better results.

IMG-20240901-WA0004.jpg

TEWL Detection: Assess the difference in the Improvement Rate (IR) between using microcurrent and no-current masks using the VapoMeter. Lower values indicate better results.

IMG-20240901-WA0005.jpg

Skin hydration: Due to the IonFuse mask's exceptional penetration ability, skin hydration consistently maintained at levels exceeding 150% even at the second, fourth, and eighth-hour intervals.

IMG-20240901-WA0008.jpg

Skin hydration levels remain above 150% even after 8 hours

Trans-Epidermal Water Loss (TEWL): For the regular mask (gray bar), after applying it for the second hour, water dispersion begins, becoming more pronounced by the fourth hour. By the eighth hour, the skin's natural defense mechanism starts releasing oil, leading to a partial recovery in the lost condition. However, the TEWL with the IonFuse mask has consistently maintained a good condition.

IMG-20240901-WA0007.jpg

TEWL remains negative even after 8 hours.

3D Skin Testing Results & Skin Roughness Improvement

Picture2(13).png

Before & After Images

Utilizing the IonFuse microcurrent facial mask, the impact is especially prominent, as evident in the before-and-after comparison images.

Picture2(14).png

Deep penetration and long-lasting hydration

Picture2(16).png
Picture2(18).png

Improved dullness, enhanced skin barrier

Picture2(17).png
IMG-20240901-WA0003.jpg
bottom of page